Construction assembly A0298

Lignum ID-№
A0298
Catalog number
A.2.01.O11
Source of construction assembly
Lignum, Year 2016
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433
Construction height
415 mm
Weight
237 kg/m2
U-value
≈ 0.331 W/m2K
GWP
50.89 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of hollow box element, single sheathed, without ceiling covering with air flow resistivity [r] of 5≤ r ≤50 kPa s/m², without dampening in the supporting structure, with cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 6 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 62 dB
C -3 dB
C50-3150 -6 dB
Values of footfall sound insulation
Ln,w 53 dB
CI 1 dB
CI50-2500 4 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³]
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Rigid, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation as between-rafter insulation
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Lower skin 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Assembly

Comment Cavity damping reduces cavity resonances. The relevant parameter is not bulk density but airflow resistivity (5–50 kPa·s/m²). The insulation material must fill at least 70% of the cavity height and 80% of the cavity width. See Lignum publication «Schallschutz im Holzbau», Section 4.5.

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 176 kg/m2 - - 04.006 91.136
Impact sound insulation Glass wool with dynamic stiffness s' of ≤ 6 [MN/m³] Sager, Swisspor, Zisola, Isover 2.4 kg/m2 - - 10.001.01 91.173
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Stora Enso, Swiss Krono Group, Pfleiderer, Binderholz, Novatop, Pius Schuler, Schilliger Holz 11.8 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Label swiss wood, Generic product, Schilliger Holz 15.1 kg/m2 07.003.01 91.047
Cavity dampening Fiber insulation as between-rafter insulation Flumroc, Gutex, Sager, Swisspor, Isover, Schilliger Holz 4.5 kg/m2 - - 10.008 91.173
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Stora Enso, Swiss Krono Group, Pfleiderer, Binderholz, Novatop, Pius Schuler, Schilliger Holz 11.8 kg/m2 - - 07.001 91.048
Lower skin 2nd layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Knauf, Rigips, Fermacell 16 kg/m2 - - 03.007 91.063

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
94665
UBP'21/m2
A1-A3 + C1-C4
 
┣
Environmental impact points from production (UBP_pro)
82175
UBP'21/m2
A1-A3
 
┗
Environmental impact points from disposal (UBP_dis)
12418
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
628.35
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy from production (PE_pro)
612.53
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy production, energetically consumed (PE_E_pro)
412.20
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy production, materially bound (PE_M_pro)
202.44
kWh oil-eq/m2
A1-A3
 
┗
Primary energy from disposal (PE_dis)
15.72
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
453.97
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Renewable primary energy from production (PE_RT_pro)
453.30
kWh oil-eq/m2
A1-A3
 
┃
┣
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
259.03
kWh oil-eq/m2
A1-A3
 
┃
┗
Renewable primary energy from production, materially bound (PE_RM_pro)
193.09
kWh oil-eq/m2
A1-A3
 
┗
Renewable primary energy from disposal (PE_RT_dis)
0.77
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
176.18
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy not renewable from manufacturing (PE_NRT_pro)
161.36
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
152.17
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.19
kWh oil-eq/m2
A1-A3
 
┗
Primary energy not renewable from disposal (PE_NRT_dis)
14.96
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
50.89
kg CO2/m2
A1-A3 + C1-C4
 
┣
Greenhouse gas emissions from manufacturing (GWP_pro)
45.86
kg CO2/m2
A1-A3
 
┗
Greenhouse gas emissions from waste disposal (GWP_dis)
4.98
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
64.61
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
17.62
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)